Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 40A Contactor for WPG3482130LKB1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 40A Contactor for WPG3482130LKB1 — 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part #1173690) is the 40-amp, 24V-coil switching relay that energizes the compressor and condenser fan in your ICP, Tempstar, or Heil WPG3482130LKB1 unit. When the thermostat calls for cooling, the 24V coil pulls in the contacts to send line voltage to the compressor. Pitted, welded, or chattering contacts are a leading cause of no-cool calls. Replacing a worn contactor restores reliable starting and protects downstream components from voltage drop and arcing.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Tempstar / Heil
Contact Rating 40A
Coil Voltage 24V
Poles 1

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil WPG3482130LKB1 package unit and other systems specifying a 1-pole 40A 24V contactor. Confirm pole count, amperage, and coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the control compartment.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Note wire positions, disconnect terminals, and unfasten the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect line, load, and coil wires per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor starts.

Signs You Need a Replacement

  • Buzzing or chattering at the contactor
  • Compressor won't engage on a cooling call
  • Visibly pitted, burned, or welded contacts
  • Coil fails to pull in with 24V present

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3482130LKB1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3482130LKB1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3482130LKB1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online