This OEM definite-purpose contactor (part 1173690) is a 1-pole unit rated 40A with a 24V coil for the ICP / Tempstar / Heil WPG3482090RKB1 packaged unit. The contactor is the electrically-operated switch that energizes the compressor and condenser fan when the 24V control circuit calls for cooling. Over time the silver contacts pit, burn, or weld from arcing, and the coil can fail open. Symptoms include a unit that won't start on a cooling call, chattering or buzzing at the contactor, contacts that stick closed so the compressor never shuts off, or visible pitting/burning on the contact faces. A worn contactor is a frequent and inexpensive cause of intermittent no-cool calls.

Specifications

Spec Value
Part Number 1173690
Part Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 1-Pole
Contact Rating 40A
Coil Voltage 24V
Model WPG3482090RKB1

Compatibility

Direct-fit OEM replacement for the ICP/Tempstar/Heil WPG3482090RKB1 packaged gas/electric unit and other ICP-family units using a 1-pole 40A 24V-coil contactor. Confirm pole count, amp rating, and 24V coil on your existing part (1173690) before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter at the line terminals.
  2. Access — Remove the electrical/control compartment panel.
  3. Document — Photograph the line, load, and 24V coil wiring before disconnecting.
  4. Remove — Disconnect all leads, unbolt the contactor from its bracket, and remove it.
  5. Install — Mount the new contactor, transfer the line, load, and 24V coil leads exactly per your photo, and tighten all terminals.
  6. Test — Restore power, place a cooling call, and verify the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Unit won't start on a cooling call despite 24V at the coil
  • Loud chattering or buzzing from the contactor
  • Contacts welded closed — compressor runs nonstop
  • Visible pitting, burning, or melted contact faces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3482090RKB1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3482090RKB1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3482090RKB1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online