Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 40A Contactor for WJA448000KTP0A1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 40A Contactor for WJA448000KTP0A1 — 24V Coil | Ships Today

SKU: 1173690 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite purpose contactor (part 1173690) is a direct replacement for ICP, Tempstar, and Heil model WJA448000KTP0A1. The contactor is the high-current relay that switches line voltage to the compressor and condenser fan motor whenever the thermostat calls for cooling. A 24V control signal energizes the coil, pulling the contacts closed; when the call ends, the coil de-energizes and the contacts open. This is a 1-pole, 40-amp contactor with a 24V coil. Contactors fail from contact pitting and burning, a chattering or open coil, or debris jamming the armature — symptoms include a unit that won't start, chattering at the contactor, or a compressor that runs continuously because welded contacts won't release.

Specifications

Spec Value
Part Number 1173690
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 1
Contact Rating 40 A
Coil Voltage 24 V
Fitment OEM

Compatibility

Engineered for ICP, Tempstar, Heil, and Comfortmaker model WJA448000KTP0A1. Confirm your existing contactor is a 1-pole unit with a 24V coil rated at or near 40A before installing. Matching pole count and coil voltage is essential for correct operation.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect switch, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser control panel cover.
  3. Document — Photograph all line, load, and 24V coil wire connections before disconnecting.
  4. Remove — Disconnect each wire, then unscrew the old contactor from its mounting bracket.
  5. Install — Mount the new contactor and reconnect every wire to its matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the unit starts.

Signs You Need a Replacement

  • Burnt, pitted, or welded contacts
  • Loud chattering or buzzing at the contactor
  • Unit won't start despite a 24V signal at the coil
  • Compressor runs nonstop because contacts won't open

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WJA448000KTP0A1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WJA448000KTP0A1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WJA448000KTP0A1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online