Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 35A Contactor for YK048GC2 — 24V Coil | Ships Today
ICP

ICP 1-Pole 35A Contactor for YK048GC2 — 24V Coil | Ships Today

SKU: 1050839 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole contactor (PN 1050839) is the main switching relay for the ICP / Heil / Tempstar YK048GC2 heat pump. Rated 35 amps with a 24-volt coil, it closes when the thermostat sends a 24VAC call, sending line voltage to the compressor and condenser fan motor. Over thousands of cycles the silver contacts pit and burn, leading to chattering, welded contacts, or a no-start condition. A failing contactor is one of the most common causes of an outdoor unit that hums but won't run, or one that won't shut off because the contacts have welded closed. Replacing it with the correct 35A, 24V-coil OEM part restores clean, reliable switching.

Specifications

Spec Value
Part Number 1050839
Type Definite-Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 1-Pole
Contact Rating 35 Amps
Coil Voltage 24 VAC
Fitment OEM

Compatibility

Built for the ICP / Heil / Tempstar YK048GC2 and other YK048G-series condensing units that use a 1-pole, 35A contactor with a 24V coil. Verify pole count, amp rating, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and unit disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical-access service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer one wire at a time, or unclip the old contactor from its bracket after labeling leads.
  5. Install — Mount the new 35A contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, place a cooling call, and confirm the contactor pulls in and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums but compressor/fan won't start.
  • Loud chattering or buzzing at the contactor.
  • Unit won't shut off (welded contacts).
  • Visibly pitted, burned, or arcing contact points.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YK048GC2 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YK048GC2 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YK048GC2 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online