Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 35A Contactor for YJ048GA2 — 24V Coil | Ships Today
ICP

ICP 1-Pole 35A Contactor for YJ048GA2 — 24V Coil | Ships Today

SKU: 1050839 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole, 35-amp contactor (part 1050839) with a 24V coil is the electrical switch that powers the compressor and condenser fan in your ICP / Tempstar / Heil YJ048GA2 outdoor unit. When the thermostat calls for cooling, the 24V control signal energizes the contactor coil, pulling the contacts closed to deliver line voltage to the compressor. Contactors are high-wear parts: pitted, welded, or chattering contacts are a leading cause of a unit that won't start, hums, or trips the breaker. Replacing a worn contactor restores reliable starts and protects the compressor.

Specifications

Spec Value
Part Number 1050839
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 1-Pole
Contact Rating 35A
Coil Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil YJ048GA2 condensing unit and other ICP-family systems specifying the 1050839 single-pole 35A 24V contactor. Confirm pole count, amp rating, and 24V coil against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel to reach the contactor.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time (or label them), unscrew the mounting screws, and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan start.

Signs You Need a Replacement

  • Compressor won't start or only buzzes/hums
  • Burnt, pitted, or welded contacts
  • Chattering or rapid clicking at the contactor
  • Intermittent cooling or breaker trips on start

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ048GA2 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ048GA2 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ048GA2 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online