Overview

This OEM single-pole 30 amp contactor with shunt (part number 1172472) is the main switching relay for the ICP/Heil/Tempstar WJH342000KTP0A2 heat pump. Its 24V control coil is energized by the thermostat call, closing the main contacts to feed line voltage to the compressor and outdoor fan motor. The integrated shunt provides the proper auxiliary path for this model. A worn contactor causes the most common no-cooling and no-heating symptoms on a heat pump: a buzzing outdoor unit that will not engage, hard starts, or a compressor that runs nonstop because the contacts have welded closed. Replacing it restores clean, reliable starting and protects the compressor.

Specifications

Spec Value
OEM Part Number 1172472
Type Definite Purpose Contactor (with Shunt)
Brand ICP / Heil / Tempstar
Poles 1 (Single-Pole)
Rating 30 Amp
Coil Voltage 24V
Application Condenser / Compressor Switching

Compatibility

Direct OEM fit for the ICP/Heil/Tempstar WJH342000KTP0A2 outdoor heat pump unit. The 30A single-pole, 24V-coil with-shunt configuration matches this model's factory specification. Confirm amperage, coil voltage, and the shunt requirement against the part you are removing before installing.

Installation Guide

  1. Safety First - Disconnect power at the outdoor disconnect and breaker; verify zero voltage at the line terminals with a multimeter.
  2. Access - Remove the outdoor unit service/electrical panel.
  3. Document - Photograph all wire positions, including the shunt connection, before disconnecting.
  4. Remove - Label and disconnect the line, load, and 24V coil wires; unscrew the old contactor.
  5. Install - Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test - Restore power, call for cooling/heating, and confirm the contacts pull in and the unit starts cleanly.

Signs You Need a Replacement

  • Outdoor unit buzzes but the compressor and fan do not start.
  • Pitted, burned, or melted contacts visible on the contactor.
  • Compressor will not shut off (welded contacts).
  • Chattering or rapid clicking on a thermostat call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WJH342000KTP0A2 - 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WJH342000KTP0A2 - 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WJH342000KTP0A2 - 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.