Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WPH4364000RKB1 — 24V Coil with Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WPH4364000RKB1 — 24V Coil with Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM single-pole definite-purpose contactor (P/N 1172472) for the ICP/Tempstar/Heil WPH4364000RKB1 packaged heat pump. Rated at 30 amps with a 24-volt control coil and an integrated shunt, the contactor is the electromechanical switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heat-pump operation. When the 24V coil is energized, the contactor pulls in and closes the line-voltage contacts that feed the outdoor unit. A failed contactor is one of the most common no-cooling service calls: pitted or welded contacts, a burned coil, or chattering points will prevent the compressor from starting or cause it to short-cycle.

Specifications

Spec Value
Part Number 1172472
Type Single-Pole (1-Pole) Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Rating 30 Amps
Coil Voltage 24 VAC
Features Integrated Shunt

Compatibility

Designed as the factory replacement for the ICP/Tempstar/Heil WPH4364000RKB1 packaged heat pump. It also fits many comparable ICP-family condensing units and heat pumps using a 1-pole 30A 24V contactor — always confirm the existing contactor's amp and coil-voltage rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and breaker, then verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the electrical service panel on the outdoor unit.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Label and disconnect each wire, unscrew the old contactor from its bracket, and lift it out.
  5. Install — Mount the new contactor, reconnect line, load, and coil wiring per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor energizes.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan will not start.
  • Visibly pitted, burned, or welded contacts.
  • Loud chattering or buzzing at the contactor on a cooling call.
  • Intermittent cooling or compressor short-cycling.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPH4364000RKB1 — 24V Coil with Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPH4364000RKB1 — 24V Coil with Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPH4364000RKB1 — 24V Coil with Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera