Overview

This OEM definite-purpose contactor (part 1172472) is a 1-pole, 30-amp unit with a 24V coil and integrated shunt, used in the ICP WPG4424060RKA1 condensing unit. When the thermostat calls for cooling, the 24V coil pulls the contacts closed to send line voltage to the compressor and condenser fan motor; the shunt maintains the unswitched leg. Contactors are a leading failure point because the contacts arc, pit, and weld over thousands of cycles. Pitted contacts cause hard starting, chatter, and reduced voltage to the compressor; welded contacts keep the unit running even when the thermostat is satisfied.

Specifications

Spec Value
Part Number 1172472
Type Definite-Purpose Contactor (w/ Shunt)
Poles 1-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP (Tempstar / Heil)

Compatibility

Designed for the ICP WPG4424060RKA1 packaged unit and related WPG-series equipment under the ICP, Tempstar, Heil, and Comfortmaker brands. Verify pole count, amp rating, and 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power, verify zero voltage with a multimeter, and discharge the run capacitor.
  2. Access — Remove the condenser control-box panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Unscrew the contactor from the bracket and transfer wires one at a time to the matching terminals on the new contactor.
  5. Install — Mount the new contactor, confirm the shunt leg and coil leads match your photo, and tighten all lugs.
  6. Test — Restore power, place a cooling call, and confirm the contacts pull in cleanly with the compressor and fan starting.

Signs You Need a Replacement

  • Buzzing, chattering, or humming at the contactor
  • Pitted, burned, or welded contacts
  • Compressor won't start or won't shut off
  • Visible arcing or melted contactor housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4424060RKA1 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4424060RKA1 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4424060RKA1 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.