This OEM single-pole contactor (part #1172472) is the factory switching relay for the ICP/Tempstar/Heil WPG4244060LKA1 system. Rated 30 amps with a 24-volt control coil and an integrated shunt, the contactor acts as the high-current on/off switch that energizes the load whenever the thermostat calls. When the 24V coil is energized, the contacts pull in and pass line voltage; when the call ends, they spring open. Contactors endure thousands of make/break cycles, so the contacts eventually pit, burn, or weld - causing failed starts, chattering, or a unit that will not shut off. The shunt design helps manage current flow and protects the contact set for longer service life.

Specifications

Spec Value
Part Number 1172472
Type Contactor, 1-Pole, with Shunt
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24V
Poles 1
Fitment OEM

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil WPG4244060LKA1. Verify pole count, amp rating, and 24V coil match your original before installing.

Installation Guide

  1. Safety First - Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access - Remove the service panel to reach the contactor.
  3. Document - Photograph every line, load, and coil wire before disconnecting.
  4. Remove - Unscrew the mounting, transfer wires one at a time, and remove the old contactor.
  5. Install - Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test - Restore power and confirm the contacts pull in on a call and drop out cleanly.

Signs You Need a Replacement

  • Buzzing or chattering when the system tries to engage
  • Pitted, blackened, or welded contacts
  • Unit fails to start or will not shut off
  • Coil no longer pulls the contacts in when energized

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG4244060LKA1 - 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG4244060LKA1 - 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG4244060LKA1 - 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.