Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WPA4244000RKB1 — 24V Coil with Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WPA4244000RKB1 — 24V Coil with Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM single-pole definite-purpose contactor (part number 1172472) for the ICP WPA4244000RKB1 condensing unit. Rated for 30 amps with a 24-volt control coil and an integrated shunt, this contactor is the electrical switch that energizes the compressor and condenser fan motor on every cooling call. When the 24V coil is energized, the electromagnet pulls the contacts closed and passes line voltage to the outdoor unit. Pitted or welded contacts, a burned coil, or chattering from low control voltage are among the most frequent causes of a no-cooling outdoor unit. A fresh contactor restores positive, reliable switching and protects the compressor from harmful voltage drops on start-up.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Poles 1 (Single Pole)
Resistive Rating 30 Amps
Coil Voltage 24V
Feature Integrated Shunt
Fitment OEM Replacement

Compatibility

A direct OEM replacement for the ICP WPA4244000RKB1 air conditioner. Because ICP manufactures for the Heil, Tempstar, and Comfortmaker brands, this 1-pole 30A 24V contactor commonly services matching condensing units across that family. Confirm the printed part number on your current contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the condenser service panel to expose the control compartment.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting anything.
  4. Remove — Label and disconnect the wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and transfer the wires exactly per your photo, confirming line in, load out, and the two 24V coil leads.
  6. Test — Restore power and trigger a cooling call; confirm the contacts pull in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit will not start despite a cooling call from the thermostat
  • Loud buzzing, humming, or chattering from the contactor
  • Visibly pitted, blackened, or welded contacts
  • Compressor and fan run continuously and will not shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPA4244000RKB1 — 24V Coil with Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPA4244000RKB1 — 24V Coil with Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPA4244000RKB1 — 24V Coil with Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online