Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WJH330000K000A1 — 24V Coil w/ Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WJH330000K000A1 — 24V Coil w/ Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole 30-amp contactor (part #1172472) with a 24V coil and shunt is the switching relay for the ICP/Heil/Tempstar WJH330000K000A1 heat pump. When the thermostat calls for cooling or heating, the 24V coil energizes and pulls the contacts closed, sending line voltage to the compressor and outdoor fan motor. The shunt provides the constant connection on the line side typical of single-pole designs. Contactors are one of the most common outdoor-unit failures: the contacts pit and burn from arcing over thousands of cycles, the coil can fail open, or insects/debris can jam the plunger. A failed contactor causes a unit that hums but won't start, chattering, or an outdoor unit that runs continuously and won't shut off.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor, Single-Pole, with Shunt
Brand ICP (Heil / Tempstar / Comfortmaker)
Poles 1
Contact Rating 30 Amps
Coil Voltage 24V

Compatibility

Fits the ICP/Heil/Tempstar/Comfortmaker WJH330000K000A1 heat pump and other units using a single-pole 30A definite-purpose contactor with a 24V coil. Verify pole count, amp rating, and coil voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical access panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor, reconnect line, load, and coil wiring exactly per your photo.
  6. Test — Restore power, initiate a thermostat call, and confirm the contactor pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor/fan won't start
  • Pitted, burned, or welded contacts
  • Chattering contactor or audible buzzing at the coil
  • Unit runs continuously and won't shut off (stuck contacts)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WJH330000K000A1 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WJH330000K000A1 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WJH330000K000A1 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera