Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WJA342000K000B1 — 24V Coil w/ Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WJA342000K000B1 — 24V Coil w/ Shunt | Ships Today

SKU: 1172472-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM ICP part 1172472 is a single-pole 30-amp definite-purpose contactor with a 24V coil and integrated shunt, used to switch line power to the compressor and condenser fan on ICP/Heil/Tempstar units like model WJA342000K000B1. When the thermostat calls, the 24V coil pulls the contacts closed to energize the outdoor unit. Pitted, welded or chattering contacts are a leading cause of an outdoor unit that hums but won't start, runs continuously, or cycles erratically. This direct factory replacement restores reliable switching.

Specifications

Spec Value
Part Number 1172472
Type 1-Pole Definite Purpose Contactor (w/ shunt)
Brand ICP / Heil / Tempstar
Rating 30 Amps
Coil Voltage 24V
Poles 1

Compatibility

Fits ICP, Heil, Tempstar and Comfortmaker condensing units and heat pumps using a 1-pole 30A 24V-coil contactor, including model WJA342000K000B1. Confirm pole count, amp rating and coil voltage on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit control-access panel.
  3. Document — Photograph line, load and 24V coil wiring before disconnecting.
  4. Remove — Disconnect all leads and unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect line, load and coil wires exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the unit starts.

Signs You Need a Replacement

  • Outdoor unit hums but compressor/fan won't start
  • Visibly pitted, burnt or welded contacts
  • Chattering or buzzing contactor
  • Unit won't shut off or cycles randomly

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WJA342000K000B1 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WJA342000K000B1 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WJA342000K000B1 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online