Overview

This genuine OEM 1-pole, 30-amp contactor with a 24V coil and shunt (part number 1172472) is the switching relay for the compressor and condenser fan in the ICP / Tempstar / Heil WCH5424GKA200 heat pump. When the thermostat calls, the 24V coil energizes and pulls the contacts closed to feed line voltage to the outdoor unit; the shunt completes the second leg of the circuit. As one of the most frequently replaced parts in any outdoor unit, contactors wear out as their contacts pit and burn from repeated arcing, and the coil can fail open — leaving the condenser dead while the indoor blower still runs.

Specifications

Spec Value
Part Number 1172472
Type 1-Pole Contactor with Shunt
Brand ICP (Tempstar / Heil)
Contact Rating 30A
Coil Voltage 24V
Poles 1
Fitment OEM

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil WCH5424GKA200 heat pump. The 30A rating and 24V coil match the unit's compressor and low-voltage control circuit. Verify your existing contactor's amp rating, pole count, and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the service panel on the outdoor unit to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time to the new contactor, or label them, then unscrew the old unit from its bracket.
  5. Install — Mount the new contactor and reconnect every wire per your photo, tightening all terminal screws.
  6. Test — Restore power, call for cooling/heating, and confirm the contactor pulls in and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit won't start but indoor blower runs
  • Buzzing or chattering at the contactor
  • Pitted, burned, or welded contacts
  • 24V coil reads open on a multimeter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH5424GKA200 — 24V Coil w/Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH5424GKA200 — 24V Coil w/Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH5424GKA200 — 24V Coil w/Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online