Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WCH5244GKA200 — 24V Coil with Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WCH5244GKA200 — 24V Coil with Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole 30A contactor with a 24V coil and integrated shunt (part number 1172472) fits the ICP Tempstar Heil model WCH5244GKA200. The 24V thermostat signal energizes the coil, closing the line-voltage contacts that power the compressor and condenser fan, while the shunt feeds crankcase heater or related circuits. Worn contactors typically show pitting, welding, or coil failure, producing a unit that hums but will not start, that fails to shut off, or that chatters when energized.

Specifications

Spec Value
Part Number 1172472
Type 1-Pole Contactor with Shunt
Brand ICP (Tempstar / Heil)
Contact Rating 30A
Coil Voltage 24V
Poles 1
Fitment OEM

Compatibility

Direct-fit replacement for the ICP Tempstar Heil model WCH5244GKA200 and related WCH5244 series condensing units. Confirm pole count, amp rating, and coil voltage against the existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each lead per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan start.

Signs You Need a Replacement

  • Unit hums but compressor will not start.
  • Pitted, burned, or welded contacts.
  • Chattering or buzzing when energized.
  • Compressor runs continuously and will not shut off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH5244GKA200 — 24V Coil with Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH5244GKA200 — 24V Coil with Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH5244GKA200 — 24V Coil with Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online