Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WCH4374GKB100 — 24V Coil w/ Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WCH4374GKB100 — 24V Coil w/ Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole 30-amp contactor (OEM #1172472, CONTACTOR 1P 30A 24V W/SHUNT) is the high-voltage switch for the ICP/Tempstar/Heil WCH4374GKB100 condensing unit. When the thermostat calls for cooling, the 24V coil pulls the contacts closed, sending line voltage to the compressor and condenser fan motor. The integrated shunt provides the bleed/holding path for reliable operation. Contactors are among the most common failure points in outdoor units: pitted or welded contacts, an open 24V coil, or insect/debris fouling all cause the unit to fail to start, chatter, or run continuously. A fresh OEM 1-pole 30A contactor restores clean, dependable switching.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor (1-Pole)
Brand ICP (Tempstar / Heil / Comfortmaker)
Contact Rating 30 Amps
Poles 1
Coil Voltage 24V (with shunt)
Application AC Compressor / Condenser

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil WCH4374GKB100 and other ICP-family condensing units using a 1-pole, 30A, 24V-coil definite-purpose contactor. Confirm pole count (1), amp rating (30A), and coil voltage (24V) match your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical access panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew and lift out the old contactor.
  5. Install — Mount the new contactor, reconnect line, load, and 24V coil leads per your photo.
  6. Test — Restore power and call for cooling; confirm the contactor pulls in and the unit starts.

Signs You Need a Replacement

  • Outdoor unit won't start, or only starts when the contactor is pressed by hand.
  • Loud buzzing, chattering, or humming at the contactor.
  • Pitted, burned, or welded-together contacts.
  • Unit runs nonstop and won't shut off (stuck closed).

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH4374GKB100 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH4374GKB100 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH4374GKB100 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online