Overview

This is a genuine OEM single-pole definite purpose contactor (OEM #1172472) for the ICP/Heil/Tempstar WCH4184GKA100 heat pump. The contactor is the electromechanical relay that energizes the compressor and outdoor fan. A 24V signal from the thermostat circuit pulls the contacts closed, sending line voltage to the compressor. Rated at 30 amps with a 24V coil and an integrated shunt, this is a direct factory replacement. Contactors are a high-wear item — the contacts arc every time they open and close, eventually pitting or welding.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor, Single-Pole
Brand ICP / Heil / Tempstar
Poles 1
Contact Rating 30 Amps
Coil Voltage 24V
Features Integrated shunt

Compatibility

Built as the factory replacement for the ICP/Heil/Tempstar WCH4184GKA100 condensing unit. This 1-pole 30A 24V configuration is shared across many ICP-family outdoor units — match the amp rating and coil voltage to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph all wire positions before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contacts pull in and the compressor and fan start on a call.

Signs You Need a Replacement

  • Outdoor unit is dead and silent on a cooling/heating call
  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Compressor won't shut off (contacts stuck closed)

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH4184GKA100 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH4184GKA100 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH4184GKA100 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online