Overview

This OEM single-pole 30-amp contactor with shunt (part number 1172472) is the power relay that switches line voltage to the compressor and condenser fan on your ICP/Tempstar/Heil WCH3362GKR500. A 24V coil pulls the contacts closed whenever the thermostat calls, and the built-in shunt maintains the unswitched leg. Contactors wear out from arcing — pitted or welded contacts cause hard starting, chattering, or a unit that won't run at all.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor, 1-Pole, with Shunt
Brand ICP / Tempstar / Heil
Contact Rating 30A
Coil Voltage 24V
Poles 1
Fit OEM Direct Replacement

Compatibility

Direct factory replacement for the ICP WCH3362GKR500 condensing unit and other ICP-family units that shipped with a 1-pole 30A 24V contactor (part 1172472). Confirm pole count, amp rating, and 24V coil before installing.

Installation Guide

  1. Safety First – Disconnect power and verify zero voltage with a multimeter.
  2. Access – Remove the outdoor unit's electrical access panel.
  3. Document – Photograph all line, load, and 24V coil connections before removing leads.
  4. Remove – Transfer the wires one at a time, or label each, then unscrew and remove the old contactor.
  5. Install – Mount the new contactor and reconnect line, load, and coil terminals exactly as photographed.
  6. Test – Restore power and confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Buzzing or chattering from the contactor on a cooling call.
  • Pitted, burned, or welded contacts.
  • Compressor and fan won't start even though the coil is energized.
  • Visible arcing or melted housing.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3362GKR500 – 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3362GKR500 – 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3362GKR500 – 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online