Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WCH3362GKR2 — 24V Coil w/Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WCH3362GKR2 — 24V Coil w/Shunt | Ships Today

SKU: 1172472-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 1-pole 30-amp definite purpose contactor (ICP part 1172472) with a 24V coil and integrated shunt switches line power to the compressor and condenser fan on the ICP WCH3362GKR2 heat pump. When the thermostat calls and the 24V coil energizes, the contactor pulls in and sends high-voltage power to the compressor. Contactors are one of the most common HVAC failure points — the contacts pit, burn, and weld over thousands of cycles. Symptoms of a failing contactor include a unit that won't start, a loud humming or buzzing at the contactor, contacts that stick closed so the unit never shuts off, or burnt/pitted contact faces.

Specifications

Spec Value
Part Number 1172472
Type 1-Pole Definite Purpose Contactor (w/Shunt)
Brand ICP (Tempstar / Heil / Comfortmaker)
Rating 30 Amp
Coil Voltage 24 VAC
Poles 1
Fitment OEM

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil WCH3362GKR2 heat pump and other units in the WCH3362 series that use a 1-pole 30A / 24V contactor. Confirm pole count, amp rating, and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit's electrical service panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Move the line, load, and 24V coil wires off one at a time, then unbolt the old contactor.
  5. Install — Mount the new contactor and transfer each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor starts on a cooling call.

Signs You Need a Replacement

  • Pitted, burnt, or welded contact faces
  • Loud humming or chattering when energized
  • Compressor won't start or won't shut off
  • Visible arcing or melted contactor housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3362GKR2 — 24V Coil w/Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3362GKR2 — 24V Coil w/Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3362GKR2 — 24V Coil w/Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online