This OEM single-pole contactor (part #1172472) is the main switching relay for the ICP WCH3314GKC100 heat pump. Rated at 30 amps with a 24-volt control coil and integrated shunt, it passes line voltage to the compressor and outdoor fan motor whenever the thermostat calls for cooling or heating. Each time the 24V coil energizes, the contacts close under load; over years of cycling they pit, arc, and eventually weld shut or fail to make contact. A worn contactor is a leading cause of no-cool and no-start calls, often showing up as a buzzing condenser, contacts that stick closed so the unit won't shut off, or a system that ignores the thermostat entirely.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor, Single Pole
Brand ICP (Tempstar / Heil / Comfortmaker)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 1
Features Integrated shunt

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WCH3314GKC100 heat pump condensing unit, and a common service replacement across single-stage 24V residential condensers using a 1-pole 30A contactor. Confirm coil voltage and amp rating against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line and low-voltage wires before disconnecting.
  4. Remove — Transfer the line, load, and 24V coil leads off the old contactor one terminal at a time.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan start on a call.

Signs You Need a Replacement

  • Loud buzzing or humming at the outdoor unit
  • Pitted, blackened, or welded contacts
  • Compressor won't start or won't shut off
  • Coil clicks but contacts fail to close

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3314GKC100 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3314GKC100 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3314GKC100 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.