Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor for WCH3242GKR3 — 24V Coil with Shunt | Ships Today
ICP

ICP 1-Pole 30A Contactor for WCH3242GKR3 — 24V Coil with Shunt | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 1-pole 30-amp definite purpose contactor with a 24V coil and built-in shunt is the high-voltage switch that powers the compressor and condenser fan on your ICP Tempstar Heil WCH3242GKR3 heat pump. On a thermostat call, the 24V coil pulls the contacts closed and sends line voltage to the compressor. Pitted, welded, or non-pulling contacts are among the most common causes of a no-cool / no-heat outdoor unit. Replaces OEM part number 1172472 (CONTACTOR 1P 30A 24V W/SHUNT).

Specifications

Spec Value
Part Number 1172472
Type 1-Pole Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC (with shunt)
Poles 1

Compatibility

Direct-fit replacement for the ICP Tempstar Heil WCH3242GKR3 heat pump and related WCH3242 R3-series condensing units using a single-pole 30A 24V contactor. Verify your existing contactor is rated 30A with a 24V coil before installing.

Installation Guide

  1. Safety First — Shut off the disconnect and breaker, then verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the condenser service panel to reach the contactor.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer or label wires one at a time, then unscrew the contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power and confirm the contacts pull in and the compressor energizes on a thermostat call.

Signs You Need a Replacement

  • Outdoor unit won't start despite a thermostat call.
  • Buzzing, humming, or chattering from the contactor.
  • Burned, pitted, or welded contacts.
  • Compressor runs only when the contactor is pressed in by hand.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3242GKR3 — 24V Coil with Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3242GKR3 — 24V Coil with Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3242GKR3 — 24V Coil with Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online