This OEM single-pole definite-purpose contactor (part number 1172472) is the high-voltage switch that powers the compressor and condenser fan motor in your ICP WCA3364GKN200 condensing unit. Rated for 30 amps with a 24-volt control coil and a built-in shunt, it closes the line circuit every time the thermostat calls for cooling. Contactors take heavy electrical wear — arcing pits the contacts, the coil can open or short, and stuck contacts can run the compressor continuously. A fresh 1172472 restores crisp, reliable switching and protects the compressor from damaging low-voltage and short-cycling conditions.

Specifications

Spec Value
Part Number 1172472
Type Single-Pole (1P) Definite Purpose Contactor w/ Shunt
Brand ICP / Tempstar / Heil
Current Rating 30 Amps
Coil Voltage 24 VAC
Poles 1
Fit OEM Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil WCA3364GKN200 condensing unit. The 1172472 is also used across many ICP-family split-system air conditioners and heat pumps specifying a 1-pole 30A 24V contactor — confirm against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the contactor with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph every line, load, and 24V coil connection before disconnecting.
  4. Remove — Label and disconnect all leads, then unbolt the old contactor from its bracket.
  5. Install — Mount the new 1172472 contactor and reconnect each wire per your photo.
  6. Test — Restore power, call for cooling, and confirm clean pull-in with the compressor and fan running.

Signs You Need a Replacement

  • Buzzing or chattering at the condenser when cooling is called.
  • Burned, pitted, or melted contact surfaces.
  • Compressor won't start despite 24V at the coil.
  • Unit runs continuously because contacts have welded shut.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCA3364GKN200 — 24V Coil w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCA3364GKN200 — 24V Coil w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCA3364GKN200 — 24V Coil w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online