This genuine OEM single-pole 30-amp definite purpose contactor (OEM #1172472) with shunt is the high-voltage relay that powers the compressor and condenser fan motor in the ICP/Tempstar/Heil WCH3374GKC200 heat pump. When the thermostat calls for cooling or heating, the 24V coil pulls the contacts closed and sends line voltage to the outdoor unit. Contactors are a common wear item — the contacts pit, burn, or weld over thousands of cycles, and the coil can fail open. Typical symptoms include a buzzing or chattering contactor, an outdoor unit that won't start, or one that runs continuously because the contacts have welded shut.

Specifications

Spec Value
OEM Part Number 1172472
Type Definite Purpose Contactor (w/ Shunt)
Brand ICP / Tempstar / Heil
Poles 1-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Application Compressor / Condenser Fan

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil/Comfortmaker WCH3374GKC200 condensing unit and shared chassis using the same 30A 1-pole control. Confirm a 24V coil and 1-pole configuration on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage across the line terminals with a multimeter.
  2. Access — Remove the condenser control-box/service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Mark and disconnect the wires, release the contactor from its mounting clip or screws, and lift it out.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and call for cooling; confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Buzzing, humming, or chattering from the contactor
  • Outdoor unit won't start on a cooling/heating call
  • Pitted, burned, or welded contacts
  • Unit runs nonstop because contacts won't release

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3374GKC200 — w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3374GKC200 — w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3374GKC200 — w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.