Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 30A Contactor 24V Coil for WCH3482GKR3 — OEM 1172472 | Ships Today
ICP

ICP 1-Pole 30A Contactor 24V Coil for WCH3482GKR3 — OEM 1172472 | Ships Today

SKU: 1172472 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 1-pole, 30-amp definite purpose contactor with a 24V coil and integrated shunt (part #1172472) for the ICP/Heil/Tempstar WCH3482GKR3 heat pump. The contactor is the high-voltage switch that the thermostat's 24V signal closes to energize the compressor and condenser fan motor. Its contacts carry full load current on every cycle, so they pit, burn, or weld from arcing over time. A failing contactor produces hard starting, chattering, a humming outdoor unit that won't start, or a system that won't shut off because the contacts have welded closed.

Specifications

Spec Value
Part Number 1172472
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 1-Pole (single pole, with shunt)
Contact Rating 30 Amps
Coil Voltage 24V AC
Fit OEM Replacement

Compatibility

Designed for the ICP family WCH3482GKR3 heat pump and the related WCH3482GKR4 and GKR2 revisions, plus Heil and Tempstar equivalents using the 1172472 contactor. Confirm a 1-pole, 30A, 24V coil contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the control box.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Note line, load, and 24V coil leads, disconnect them, and unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and drops out cleanly.

Signs You Need a Replacement

  • Outdoor unit hums but compressor/fan won't start
  • Loud chattering or buzzing from the contactor
  • Burnt, pitted, or welded contacts
  • System won't shut off (welded closed contacts)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WCH3482GKR3 — OEM 1172472 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WCH3482GKR3 — OEM 1172472 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WCH3482GKR3 — OEM 1172472 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online