Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for YK042GC2 — 24V Coil | Ships Today
ICP

ICP 1-Pole 25A Contactor for YK042GC2 — 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 1-pole, 25-amp contactor (part #1050699) with a 24V coil is the high-voltage switch that powers up the compressor and condenser fan on your ICP/Tempstar/Heil YK042GC2 unit. When the thermostat calls, the 24V coil pulls the contacts closed to feed line voltage to the outdoor components. Over time the contacts pit, burn, weld, or chatter, and the coil can fail open. Symptoms include the outdoor unit not starting, a buzzing or humming contactor, the unit running nonstop because the contacts welded shut, or visibly pitted and blackened contacts. This direct OEM replacement restores reliable, clean switching.

Specifications

Spec Value
Part Number 1050699
Type 1-Pole Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 25A
Coil Voltage 24V
Poles 1
Fitment OEM Replacement

Compatibility

Fits the ICP Tempstar Heil YK042GC2 and related ICP-family condensing units that originally used OEM contactor 1050699. Confirm pole count, amp rating, and 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Move the wires one at a time to the new contactor, then unmount the old one.
  5. Install — Mount the new 25A contactor and confirm each line, load, and 24V coil lead matches your photo.
  6. Test — Restore power and verify the contactor pulls in on a cooling call and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling call
  • Loud buzzing or humming from the contactor
  • Contacts are pitted, burned, or welded shut
  • Compressor runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YK042GC2 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YK042GC2 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YK042GC2 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.