This OEM single-pole 25-amp contactor (part 1050699) is the high-voltage switch that energizes the compressor and condenser fan on the ICP / Tempstar / Heil YK042G heat pump. Its 24V coil pulls the contacts closed whenever the thermostat calls, passing line voltage to the compressor. Contactors are one of the most common failure points in a condensing unit: the contacts pit and burn from constant arcing, and the coil can short or stick. Failure symptoms include a unit that hums but won't start, a compressor that won't engage, chattering at the contactor, or contacts that weld shut and keep the system running continuously.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand ICP (Tempstar / Heil / Comfortmaker)
Contact Rating 25 Amps
Poles 1
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Direct OEM-fit replacement for the ICP / Tempstar / Heil YK042G heat pump. The 1-pole 25A / 24V-coil format is used across many ICP-family condensing units; verify your existing contactor's amp rating and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the condensing unit service panel to expose the contactor.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer one wire at a time or label leads, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly and the compressor starts.

Signs You Need a Replacement

  • Pitted, burnt, or welded contacts
  • Loud chattering or buzzing when the system calls
  • Compressor hums but does not start
  • System runs nonstop because contacts are stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YK042G — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YK042G — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YK042G — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online