This genuine OEM single-pole contactor (part number 1050699) for the ICP/Heil/Tempstar YK030GC2 is rated 25 amps with a 24-volt control coil. The contactor is the high-current switch that powers the compressor and condenser fan motor whenever the thermostat calls for cooling. The 24V coil pulls the contacts closed; over time the contacts pit and burn, the coil weakens, or the contactor chatters — causing hard starts, no-cool calls, or a unit that won't energize at all. A fresh contactor restores clean, reliable switching of the outdoor unit.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Heil / Tempstar
Contact Rating 25 Amps
Coil Voltage 24 VAC
Poles 1
Fitment OEM

Compatibility

Designed for the ICP/Heil/Tempstar YK030GC2 condensing unit and related family models that use a 1-pole, 25A, 24V-coil contactor. Confirm amp rating and coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photo all line, load, and coil wires before disconnecting.
  4. Remove — Unscrew the old contactor from its bracket and transfer wires one at a time.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, place a cooling call, and confirm the contacts pull in and the unit runs.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling call
  • Loud buzzing or chattering from the contactor
  • Pitted, burnt, or welded contacts
  • Compressor and fan run intermittently or hard-start

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YK030GC2 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YK030GC2 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YK030GC2 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.