Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for YJ030GA2 — 24V Coil | Ships Today
ICP

ICP 1-Pole 25A Contactor for YJ030GA2 — 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole definite purpose contactor (part #1050699) is the electrical switch that energizes the compressor and condenser fan in your ICP/Tempstar/Heil YJ030GA2 heat pump. When the 24-volt coil receives a call from the thermostat, the contacts close and send line voltage to the outdoor unit. Rated at 25 amps with a 24V control coil, the contactor cycles every time the system runs, so its contacts gradually pit and burn. Worn contacts cause buzzing, hard starts, and units that won't energize, while contacts welded shut leave the compressor running nonstop.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Tempstar / Heil
Contact Rating 25 Amps
Coil Voltage 24V
Poles 1

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil YJ030GA2 heat pump and other condensing units that originally shipped with a 1-pole 25A 24V definite purpose contactor. Confirm coil voltage (24V) and amp rating against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the condenser unit service panel.
  3. Document — Photograph every wire and terminal location before disconnecting anything.
  4. Remove — Move the line, load, and 24V coil wires off the old contactor, then unscrew it from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, place a thermostat call, and confirm the contacts pull in and the compressor/fan start.

Signs You Need a Replacement

  • Loud buzzing or chattering from the outdoor unit
  • Compressor and fan won't start on a cooling/heating call
  • Burned, pitted, or melted contact points
  • Unit runs continuously and won't shut off (contacts welded closed)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ030GA2 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ030GA2 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ030GA2 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online