Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for YJ024GA3 — 24V Coil | Ships Today
ICP

ICP 1-Pole 25A Contactor for YJ024GA3 — 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 1-pole 25-amp contactor with a 24V control coil (part number 1050699) switches line-voltage power to the compressor and condenser fan in your ICP YJ024GA3 heat pump. When the thermostat calls, the 24V coil pulls the contacts closed and energizes the outdoor unit; on satisfy, the coil de-energizes and the contacts open. A contactor's contacts erode and pit with every cycle, eventually welding shut (unit runs constantly) or failing to close (unit won't start). The 24V coil itself can also burn open. Replacing a worn contactor is one of the most common and cost-effective heat-pump repairs.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Heil / Tempstar
Rating 25 Amps
Coil Voltage 24V
Poles 1

Compatibility

Fits the ICP YJ024GA3 condensing unit and other ICP-family (Heil, Tempstar, Comfortmaker) systems calling for a 1-pole 25A contactor with a 24V coil. Verify pole count, amp rating, and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photo all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unscrew the contactor from its mounting, and remove.
  5. Install — Mount the new contactor, reconnect line, load, and coil leads per your photo, and torque terminals snug.
  6. Test — Restore power, call for cooling/heating, and confirm the contactor pulls in and the unit starts.

Signs You Need a Replacement

  • Outdoor unit runs continuously (contacts welded closed)
  • Unit won't start or chatters when energized
  • Pitted, burned, or corroded contact surfaces
  • 24V coil reads open or buzzes loudly

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ024GA3 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ024GA3 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ024GA3 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online