This is a genuine OEM 1-pole, 25-amp contactor with a 24V coil (part number 1050699) for the ICP/Tempstar/Heil YJ018GA2 condensing unit. The contactor is the high-voltage switch that powers the compressor and outdoor fan: when the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the outdoor unit. Over time the contacts pit, arc, and weld, while the coil can burn out or chatter. A failing contactor causes hard starts, buzzing, intermittent operation, or an outdoor unit that won't run at all. This single-pole contactor is rated at 25 amps with a 24V control coil for a direct OEM replacement.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 1-Pole
Contact Rating 25A
Coil Voltage 24V
Application AC Compressor / Condenser Fan
Fit OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil YJ018GA2 condensing unit and other ICP-family units using the 1-pole 25A 24V-coil contactor 1050699. Match poles, amp rating, and coil voltage to your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the condensing unit's electrical access panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Transfer one wire at a time or label each lead, then unscrew the old contactor from its bracket.
  5. Install — Mount the new 1050699 contactor and reconnect every line, load, and coil wire exactly per your photo.
  6. Test — Restore power and start a cooling cycle to confirm the contactor pulls in cleanly and the compressor and fan run.

Signs You Need a Replacement

  • Loud buzzing or chattering from the contactor when cooling is called.
  • Outdoor unit runs intermittently or won't start.
  • Pitted, burnt, or welded contacts visible on the old part.
  • 24V coil tests open or fails to pull the contacts closed.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ018GA2 — 24V Coil 1050699 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ018GA2 — 24V Coil 1050699 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ018GA2 — 24V Coil 1050699 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online