Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for YJ018G2 — 24V Coil | Ships Today
ICP

ICP 1-Pole 25A Contactor for YJ018G2 — 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part number 1050699) is the electrically controlled switch that energizes the compressor and condenser fan in your ICP YJ018G2 heat pump. When the thermostat calls for cooling or heating, the 24V control circuit energizes the contactor coil, pulling the contacts closed to deliver line voltage to the compressor and outdoor fan motor. Rated for 25 amps with a 24-volt coil, this 1-pole contactor is a high-cycle component that wears out over time. Failure symptoms include a buzzing or chattering outdoor unit, pitted or welded contacts, a unit that won't start, or a compressor that runs continuously because the contacts have fused shut.

Specifications

Spec Value
Part Number 1050699
Type 1-Pole Definite Purpose Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Contact Rating 25 Amps
Coil Voltage 24 VAC
Poles 1

Compatibility

Engineered for the ICP YJ018G2 condensing unit and shared across many ICP-family models sold under the Tempstar, Heil, and Comfortmaker brands. Always confirm your existing contactor's amp and coil-voltage ratings match (25A / 24V) before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the condenser control-panel access cover.
  3. Document — Photograph all wires and terminal positions before disconnecting anything.
  4. Remove — Label and disconnect line, load, and 24V coil wires, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power and confirm the contacts pull in cleanly with no chatter when the system calls.

Signs You Need a Replacement

  • Loud buzzing or chattering from the outdoor unit
  • Pitted, burnt, or welded-shut contacts
  • Compressor and fan won't start despite a thermostat call
  • Outdoor unit runs nonstop because contacts are stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YJ018G2 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YJ018G2 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YJ018G2 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.