Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for YG042GC9 — 24V Coil OEM 1050699 | Ships Today
ICP

ICP 1-Pole 25A Contactor for YG042GC9 — 24V Coil OEM 1050699 | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM single-pole (1P) 25-amp contactor with a 24V coil (part number 1050699) for the ICP / Heil / Tempstar YG042GC9 heat pump. The contactor is the high-voltage switch for the outdoor unit: when the thermostat sends a 24V signal to the coil, the contactor pulls in and passes line voltage to the compressor and condenser fan motor. A worn contactor develops pitted, burned, or welded contacts that cause hard starts, chatter, or a unit that won't shut off.

Specifications

Spec Value
Part Number 1050699
Part Type Definite Purpose Contactor
Poles 1 (single-pole)
Contact Rating 25A
Coil Voltage 24V
Brand ICP / Heil / Tempstar
Fit OEM replacement

Compatibility

Factory replacement contactor for the ICP / Heil / Tempstar YG042GC9 condensing unit. As an ICP family part, OEM 1050699 also fits the equivalent Comfortmaker, Heil, and Tempstar units that shipped with this 1-pole 25A 24V-coil contactor.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Disconnect the wires, release the mounting screws/clip, and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor/fan energize cleanly.

Signs You Need a Replacement

  • Unit won't start, or chatters/buzzes when calling for cooling
  • Pitted, blackened, or welded-together contacts
  • Compressor and fan won't shut off when the call ends
  • Burnt smell or melted housing at the contactor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG042GC9 — 24V Coil OEM 1050699 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG042GC9 — 24V Coil OEM 1050699 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG042GC9 — 24V Coil OEM 1050699 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online