Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for YG042GA1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 25A Contactor for YG042GA1 — 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole, 25-amp definite purpose contactor (ICP part number 1050699) is the electrical switch that powers the compressor and condenser fan on your ICP / Heil / Tempstar YG042GA1 unit. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor; when the call ends, the contacts open. Contactors are high-wear items — the contact points pit and burn over thousands of cycles, eventually welding shut or failing to close. A failed contactor is one of the most common no-cool service calls.

Specifications

Spec Value
Part Number 1050699
Description Contactor 1P 25A 24V S
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 1-Pole
Contact Rating 25 Amps
Coil Voltage 24V

Compatibility

Direct OEM-fit replacement for the ICP / Heil / Tempstar YG042GA1 condensing unit. The 1050699 1-pole 25A / 24V contactor is widely used across ICP-family condensers and heat pumps; confirm pole count, amp rating, and 24V coil voltage match your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unscrew the contactor from the bracket, and lift it out.
  5. Install — Mount the new contactor, reconnect all wires exactly per your photo, and confirm the coil leads land on the 24V terminals.
  6. Test — Restore power, call for cooling, and verify the contactor pulls in and the compressor and fan energize.

Signs You Need a Replacement

  • System won't start even though the thermostat is calling for cooling.
  • Loud buzzing, humming, or chattering from the contactor.
  • Compressor runs continuously and won't shut off (contacts welded closed).
  • Pitted, blackened, or burned contact points on inspection.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG042GA1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG042GA1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG042GA1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online