This genuine OEM single-pole definite-purpose contactor (part number 1050699) is rated 25 amps with a 24-volt coil and serves the ICP Tempstar Heil YG030GA1 condensing unit. The contactor is the electrically operated switch that closes the line-voltage circuit to the compressor and condenser fan whenever the thermostat calls for cooling. The 24V coil is energized by the control transformer; when energized it pulls the contacts closed to send power to the compressor. Pitted, welded, or chattering contacts are a leading cause of no-cool calls — a failed contactor either won't pass power (unit dead) or won't release (unit runs continuously).

Specifications

Spec Value
Part Number 1050699
Type Definite-Purpose Contactor, Single-Pole
Brand ICP / Tempstar / Heil / Comfortmaker
Contact Rating 25 Amps
Poles 1
Coil Voltage 24V AC
Fit OEM Replacement

Compatibility

A direct OEM replacement for the ICP/Tempstar/Heil YG030GA1 outdoor unit and other ICP-family condensers using a 25A single-pole, 24V-coil contactor. Confirm pole count (1), amperage (25A), and coil voltage (24V) against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage across the line terminals with a multimeter.
  2. Access — Remove the condenser electrical service panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unscrew the contactor mounting screws, and lift out the old contactor.
  5. Install — Mount the new contactor, then reconnect line, load, and coil leads exactly per your photos.
  6. Test — Restore power and call for cooling; confirm the contacts pull in and the compressor and fan energize.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling call (no contact pull-in)
  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or welded contacts that won't open
  • Compressor runs continuously even after the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG030GA1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG030GA1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG030GA1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.