Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for YG024GC9 — 1050699 24V Coil | Ships Today
ICP

ICP 1-Pole 25A Contactor for YG024GC9 — 1050699 24V Coil | Ships Today

SKU: 1050699 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The 1050699 is the OEM 1-pole, 25-amp contactor with a 24V coil used in the ICP / Tempstar / Heil YG024GC9 condensing unit. The contactor is the high-voltage switch that powers the compressor and outdoor fan: when the thermostat sends 24V to the coil, the contacts pull in and energize the unit. Over years of cycling, the contacts pit and burn or the coil weakens, causing the unit to chatter, fail to start, or weld closed and run nonstop. This is a direct OEM 25A single-pole replacement with a 24V hold coil, matching the original amperage, pole count, and footprint for the YG024GC9.

Specifications

Spec Value
Part Number 1050699
Type Definite purpose contactor, 1-pole
Brand ICP / Tempstar / Heil
Contact Rating 25A
Coil Voltage 24V
Poles 1
Fitment OEM direct replacement

Compatibility

Fits the ICP Tempstar Heil YG024GC9 and ICP-family condensing units originally equipped with the 1-pole 25A 24V contactor 1050699. Verify pole count (1), amp rating (25A), and coil voltage (24V) against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the contactor.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew the old contactor from the bracket.
  5. Install — Mount the new 1050699 contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly and the unit starts.

Signs You Need a Replacement

  • Buzzing or chattering at the contactor
  • Pitted, burned, or welded contacts
  • Outdoor unit won't start or won't shut off
  • 24V at the coil but contacts don't pull in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG024GC9 — 1050699 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG024GC9 — 1050699 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG024GC9 — 1050699 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online