Overview

This is a genuine OEM 1-pole definite purpose contactor (part number 14306501) for the ICP/Heil/Tempstar YE030G condensing unit. The contactor is the high-voltage relay that energizes the compressor and condenser fan when the 24V control circuit calls for operation. Rated at 25 amps with a 24-volt coil, this single-pole design switches one leg of line voltage while the other remains constant. A failing contactor shows up as pitted or welded contacts, a persistent hum or chatter, or an outdoor unit that won't start on a valid call. Replacing it restores reliable switching and protects the compressor from chattering damage.

Specifications

Spec Value
Part Number 14306501
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Heil / Tempstar
Contact Rating 25 Amps
Coil Voltage 24V
Poles 1

Compatibility

Factory replacement for the ICP/Heil/Tempstar YE030G outdoor unit and other ICP-family systems using a 1-pole 25A 24V contactor. Verify the part number on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel on the condensing unit.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Note line, load, and 24V coil leads, unfasten the old contactor from its bracket, and transfer wires one at a time.
  5. Install — Mount the new contactor and reconnect line, load, and coil wires exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor and fan energize on a call.

Signs You Need a Replacement

  • Humming, buzzing, or chattering from the outdoor unit
  • Burned, pitted, or welded contacts on the old part
  • Compressor and fan fail to start on a valid call
  • Contacts stick closed and won't release

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YE030G — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YE030G — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YE030G — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.