This ICP single-pole contactor (OEM part 14306501, 25A, 24V coil) is the electrically-operated switch that delivers line voltage to the compressor and condenser fan on your YD030GA heat pump. A 24V signal from the control board energizes the coil, pulling the contacts closed to start the outdoor unit. Contactors fail from pitted or welded contacts, an open coil, or chattering — leading to a unit that won't start, won't shut off, or hums and buzzes at the contactor.

Specifications

Spec Value
Part Number 14306501
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 1-Pole
Contact Rating 25A
Coil Voltage 24V
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil YD030GA heat pump and related units that originally used the 1-pole 25A contactor 14306501. Confirm pole count, amp rating, and 24V coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel on the outdoor unit.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and the compressor/fan start normally.

Signs You Need a Replacement

  • Outdoor unit won't start or won't shut off
  • Loud humming or buzzing at the contactor
  • Pitted, burned, or welded contacts
  • No continuity across the 24V coil

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YD030GA — 24V Coil OEM 14306501 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YD030GA — 24V Coil OEM 14306501 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YD030GA — 24V Coil OEM 14306501 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.