This is a genuine OEM single-pole definite purpose contactor (part #14306501, "CONTACTOR 1P 25A 24V X") for the ICP / Tempstar / Heil YD024GA condensing unit. The contactor is the high-current relay that switches line voltage to the compressor and condenser fan motor whenever the 24V thermostat circuit energizes the coil. It is rated 25 amps with a 24V control coil. Over thousands of cycles the silver contacts pit, burn, and weld, and the coil can fail open — leaving the outdoor unit silent (no compressor, no fan) even though the thermostat is calling for cooling. A pitted or chattering contactor is one of the most common no-cool service calls, and replacing this inexpensive part restores reliable operation.

Specifications

Spec Value
Part Number 14306501
Type Definite Purpose Contactor, 1-Pole
Brand ICP / Tempstar / Heil / Comfortmaker
Contact Rating 25A
Coil Voltage 24V
Poles 1

Compatibility

Directly fits the ICP/Tempstar/Heil YD024GA and other ICP-family condensers originally supplied with the 25A, 24V, 1-pole contactor 14306501. Verify amperage, coil voltage, and pole count against your old contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the control area.
  3. Document — Photograph all line, load, and 24V coil wire connections before disconnecting.
  4. Remove — Label and disconnect the wires, unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor, transfer the wires terminal-for-terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit won't start though the thermostat is calling for cool
  • Buzzing, humming, or chattering from the contactor
  • Pitted, burned, or welded contacts that won't release
  • 24V coil reads open or fails to pull the contacts in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YD024GA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YD024GA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YD024GA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online