This genuine OEM 1-pole 25A contactor with a 24V coil (part number 1173689) is the switching relay that energizes line-voltage loads on the ICP/Tempstar/Heil WPG3362060RKB1. When the control board or thermostat sends a 24V signal to the coil, the contactor pulls in and closes its 25A power contacts; when the call ends, it drops out and opens the circuit. Contactors are high-cycle wear parts and fail from pitted or welded contacts, a burned-out coil, or insects and debris jamming the armature. Typical symptoms include a unit that won't start, a chattering or buzzing contactor, contacts that stay welded closed so the load never shuts off, or visible arcing and pitting on the contact faces. Replacing it with the correct OEM 25A / 24V-coil contactor restores clean, reliable switching.

Specifications

Spec Value
OEM Part Number 1173689
Part Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 1 (Single Pole)
Contact Rating 25 Amps
Coil Voltage 24V
Fits Model WPG3362060RKB1
Fitment Genuine OEM

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil WPG3362060RKB1. The single-pole 25A rating and 24V coil match the factory control circuit and mounting footprint. Confirm OEM part number 1173689, the pole count, and 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter on the line terminals.
  2. Access — Remove the electrical compartment service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Disconnect the wires, remove the mounting screws, and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and drops out cleanly when satisfied.

Signs You Need a Replacement

  • Unit won't start or won't shut off (welded contacts)
  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or arcing contact faces
  • Coil reads open or no longer pulls the armature in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3362060RKB1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3362060RKB1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3362060RKB1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.