Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 25A Contactor for WPG3242060LKB1 — 24V Coil | Ships Today
ICP

ICP 1-Pole 25A Contactor for WPG3242060LKB1 — 24V Coil | Ships Today

SKU: 1173689 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM single-pole contactor (part 1173689) is the electrical switch that sends line voltage to the compressor and condenser fan in your ICP WPG3242060LKB1 unit. When the thermostat calls for cooling, the 24V coil energizes and pulls the contacts closed; when the call ends, the contacts open and shut the equipment down. Rated for 25A with a 1-pole design and a 24V control coil, it handles the high-current switching cycles the outdoor section sees every day. Contactor failure is one of the most common no-cooling causes — pitted or welded contacts, a burned coil, or insects lodged under the armature all keep the system from starting or stopping correctly.

Specifications

Spec Value
Part Number 1173689
Type Definite Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Poles 1-Pole
Contact Rating 25A
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Built as the direct OEM replacement contactor for the ICP WPG3242060LKB1 package unit, also sold under the Heil, Tempstar, and Comfortmaker labels. Verify pole count, amp rating, and 24V coil voltage against the original before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage at the contactor with a multimeter.
  2. Access — Remove the service panel to reach the contactor.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Disconnect the leads, release the contactor from its mounting clip or screws, and lift it out.
  5. Install — Mount the new contactor and reconnect the line, load, and coil wires exactly per your photo.
  6. Test — Restore power, place a call for cooling, and confirm the contacts pull in and the compressor and fan energize.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling call
  • Buzzing or chattering at the contactor
  • Pitted, burned, or welded contacts
  • Compressor and fan won't shut off when the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPG3242060LKB1 — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPG3242060LKB1 — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPG3242060LKB1 — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online