This genuine OEM single-pole contactor (part number 1050699) is rated 25 amps with a 24V coil and switches line voltage to the compressor and condenser fan on your ICP / Heil / Tempstar YG042G. When the thermostat calls for cooling, the 24V coil pulls the contactor closed, energizing the outdoor components. Contactors fail from pitted or welded contacts and burned coils — symptoms include a unit that won't start, a humming or chattering contactor, or an outdoor unit that runs continuously and won't shut off. At 25A and 1-pole, this is a direct OEM-rated replacement that restores clean, reliable switching.

Specifications

Spec Value
Part Number 1050699
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 1 (Single-Pole)
Contact Rating 25 Amps
Coil Voltage 24V
Fits Model YG042G

Compatibility

Direct-fit replacement for the ICP, Heil, Comfortmaker, and Tempstar YG042G condensing unit. Confirm the pole count (1), amp rating (25A), and 24V coil against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical access panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew and lift out the old contactor.
  5. Install — Mount the new 1050699 contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit won't start or buzzes without engaging
  • Burned, pitted, or welded contacts
  • Compressor runs and won't shut off (stuck contacts)
  • Chattering contactor or no continuity when the coil is energized

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YG042G — OEM Part 1050699 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YG042G — OEM Part 1050699 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YG042G — OEM Part 1050699 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online