Overview

This is a genuine OEM single-pole contactor (Part No. 14306504) for the ICP/Tempstar/Heil YF018G condensing unit. The contactor is the electromagnetic switch that energizes the compressor and condenser fan motor on a call for cooling. A 24V signal pulls in the coil, closing the 14-amp rated power contacts and feeding line voltage to the compressor. Failed contactors commonly cause an outdoor unit that hums but won't start, pitted or welded contacts that keep the compressor running after the thermostat is satisfied, or a chattering coil from weak control voltage. Installing a fresh contactor restores dependable switching and prevents the short-cycling that damages compressors.

Specifications

Spec Value
Part Number 14306504
Type Definite Purpose Contactor, 1-Pole
Brand ICP (Tempstar / Heil)
Contact Rating 14 Amps
Coil Voltage 24V
Poles 1

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil YF018G and other units originally equipped with part 14306504. Confirm the existing contactor's coil voltage and amp rating against this listing before installation.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Note the spade terminal positions, pull the wires, and unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor, reconnect each wire exactly per your photo, including the 24V coil leads.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor starts.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor won't start.
  • Burned, pitted, or welded contacts visible on the old part.
  • Compressor keeps running after the thermostat is satisfied.
  • Loud chattering or clicking from the contactor during operation.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YF018G — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YF018G — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YF018G — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online