Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1-Pole 14A Contactor for YC018G – 24V Coil | Ships Today
ICP

ICP 1-Pole 14A Contactor for YC018G – 24V Coil | Ships Today

SKU: 14306504 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM single-pole, 14-amp definite purpose contactor (part number 14306504) is the switching relay that powers the compressor and condenser fan on the ICP/Tempstar/Heil YC018G. When the thermostat sends a 24V signal to the coil, the contactor pulls in and closes the line-voltage circuit to the outdoor unit. Over time the silver contacts pit, burn, and weld from arcing, and the 24V coil can fail open. A bad contactor is one of the most common no-cool service calls — the unit hums but won't start, the contacts chatter, or the compressor and fan won't energize at all.

Specifications

Spec Value
Part Number 14306504
Type Single-Pole (1-Pole) Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 14 Amps
Coil Voltage 24V AC
Poles 1
Fitment OEM Replacement

Compatibility

Direct-fit replacement for the ICP/Tempstar/Heil YC018G outdoor unit and other models using the 14306504 contactor. Verify pole count (1), amp rating (14A), and 24V coil before installing.

Installation Guide

  1. Safety First – Disconnect power and verify zero voltage at the contactor line terminals with a multimeter.
  2. Access – Remove the condenser control-box service panel.
  3. Document – Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove – Label and disconnect the wires, then unscrew the old contactor from the bracket.
  5. Install – Mount the new contactor and reconnect every wire to the matching terminal per your photo.
  6. Test – Restore power, place a cooling call, and confirm the contactor pulls in and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start.
  • Pitted, blackened, or welded contacts.
  • Contactor chatters or pulls in intermittently.
  • No 24V continuity through the coil.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP YC018G – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP YC018G – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP YC018G – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online