Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1/5 HP 3-Speed Blower Motor for WFML045A024B3 — Furnace Blower | Ships Today
ICP

ICP 1/5 HP 3-Speed Blower Motor for WFML045A024B3 — Furnace Blower | Ships Today

SKU: 1185007 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM blower motor (part number 1185007) is the 1/5 HP, 3-speed direct-drive motor that powers the indoor blower on your ICP / Heil / Tempstar WFML045A024B3 gas furnace. It drives the blower wheel that circulates conditioned air through your ductwork on both heating and cooling cycles. When a blower motor fails, you lose airflow entirely — leading to overheating limit trips in heat mode, frozen coils in cooling mode, and rooms that never reach setpoint. Worn bearings, an open winding, or a failed run capacitor can all take this motor down. The 3-speed design lets the installer tap the correct CFM for heating, cooling, and continuous-fan operation, matching the factory airflow profile of the WFML045 cabinet.

Specifications

Spec Value
Part Number 1185007
Type Direct-drive blower motor
Horsepower 1/5 HP
Speeds 3-speed
Brand ICP / Heil / Tempstar / Comfortmaker
Application Furnace blower
Fit OEM direct replacement

Compatibility

Built for the ICP WFML045A024B3 furnace and shared across many Heil, Tempstar, Comfortmaker, and Arcoaire units using a 1/5 HP 3-speed blower motor. Confirm shaft diameter, rotation, and speed-tap wiring against your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage at the motor leads with a multimeter; discharge the run capacitor.
  2. Access — Remove the blower compartment panel and slide out the blower assembly.
  3. Document — Photograph the speed-tap wiring, capacitor leads, and blower-wheel position on the shaft before disconnecting.
  4. Remove — Loosen the wheel set screw, pull the wheel, and unbolt the old motor from the blower housing.
  5. Install — Mount the new motor, transfer the blower wheel at the same depth, reconnect the speed taps and capacitor per your photo.
  6. Test — Restore power and confirm smooth start-up, correct rotation, and proper airflow on each speed.

Signs You Need a Replacement

  • No airflow from the registers while the furnace runs
  • Motor hums but won't start, or starts then overheats and trips
  • Loud grinding, squealing, or rumbling bearing noise
  • Burnt smell or visible scorching at the motor windings

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WFML045A024B3 — Furnace Blower | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WFML045A024B3 — Furnace Blower | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WFML045A024B3 — Furnace Blower | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online