Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1/2 HP X-13 Blower Motor for WPG4244060RKA1 — ECM Furnace Blower | Ships Today
ICP

ICP 1/2 HP X-13 Blower Motor for WPG4244060RKA1 — ECM Furnace Blower | Ships Today

SKU: 1186862 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 1/2 HP X-13 ECM blower motor (OEM part number 1186862) drives the indoor air over the heat exchanger and evaporator coil in the ICP / Tempstar / Heil WPG4244060RKA1 packaged unit. The X-13 is a constant-torque electronically commutated motor — it uses programmed motor taps for quiet, efficient, and more consistent airflow than an older PSC motor, while drawing less power. A failing blower motor causes weak or no airflow, overheating lockouts on the heat side, frozen coils on the cool side, and rising energy bills. Bad bearings produce a grinding or humming noise; a failed module leaves the blower dead even though the rest of the unit energizes.

Specifications

Spec Value
Part Number 1186862
Type X-13 Constant-Torque ECM Blower Motor
Horsepower 1/2 HP
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Indoor furnace / air-handler blower
Fitment OEM direct replacement

Compatibility

Direct OEM fit for the ICP WPG4244060RKA1 packaged gas/electric unit and shared-platform Tempstar, Heil, and Comfortmaker WPG-series systems specifying the 1/2 HP X-13 blower motor 1186862. Verify HP, voltage, and shaft diameter against your old motor before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment panel and slide out the blower assembly.
  3. Document — Photograph the motor wiring, tap/plug positions, and blower-wheel setscrew location.
  4. Remove — Loosen the wheel setscrew, pull the wheel, unbolt the old motor from the housing, and transfer the wheel and mount.
  5. Install — Mount the new motor, reinstall the blower wheel (align the setscrew to the flat), reconnect the harness per your photo, and reinstall the assembly.
  6. Test — Restore power, run a heat and cool call, and confirm smooth, full-speed, vibration-free airflow.

Signs You Need a Replacement

  • Weak airflow or no air movement from the supply registers.
  • Grinding, squealing, or loud humming from the blower.
  • Furnace overheating / high-limit lockouts or a frozen evaporator coil.
  • Blower fails to start while the rest of the unit powers up normally.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4244060RKA1 — ECM Furnace Blower | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4244060RKA1 — ECM Furnace Blower | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4244060RKA1 — ECM Furnace Blower | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online