This is the genuine OEM 1/2 HP ECM blower motor (part number B0381106) for the ICP SUP20E230V1IA. An ECM (Electronically Commutated Motor) is a brushless, variable-speed DC motor that ramps airflow smoothly for quieter operation and meaningfully lower electricity use than a traditional PSC motor. It drives the indoor blower wheel that moves conditioned air through the ductwork. Failure symptoms include the blower not starting, surging or hunting between speeds, loud bearing noise, or the motor running hot and cutting out on thermal overload. Because ECM motors are tuned to the unit's control board, the correct OEM part ensures the programmed airflow profiles stay intact.

Specifications

Spec Value
Part Number B0381106
Type ECM Variable-Speed Blower Motor
Brand ICP (Heil / Tempstar)
Horsepower 1/2 HP
Motor Technology Electronically Commutated (ECM)
Application Indoor Blower
Fitment OEM Exact-Fit

Compatibility

Designed for the ICP SUP20E230V1IA and shared across matching ICP-family furnaces and air handlers sold under Heil, Tempstar, and Comfortmaker. Verify the B0381106 number and the motor/module orientation before ordering.

Installation Guide

  1. Safety First – Disconnect power and verify zero voltage with a multimeter; ECM modules can hold a charge.
  2. Access – Remove the blower-compartment panel and slide out the blower assembly.
  3. Document – Photograph the motor wiring, module connector, and blower-wheel position on the shaft.
  4. Remove – Loosen the wheel set screw, separate the motor from the housing, and detach the control module connector.
  5. Install – Mount the new motor, set the blower wheel to the documented depth, and reconnect the harness and module plug.
  6. Test – Restore power, run a blower call, and confirm smooth ramp-up and correct airflow at each stage.

Signs You Need a Replacement

  • Blower will not start or only hums
  • Motor surges, hunts between speeds, or cycles on and off
  • Loud grinding or bearing noise from the blower compartment
  • Motor overheats and trips on thermal overload

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns on uninstalled motors. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP SUP20E230V1IA – OEM B0381106 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP SUP20E230V1IA – OEM B0381106 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP SUP20E230V1IA – OEM B0381106 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online