Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1/2 HP Blower Motor for WPG4424090RKB1 — Furnace Blower | Ships Today
ICP

ICP 1/2 HP Blower Motor for WPG4424090RKB1 — Furnace Blower | Ships Today

SKU: WPG4424090RKB1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM motor set keeps air moving through the ICP WPG4424090RKB1 packaged gas/electric unit. The 1/2 HP blower motor (OEM 1188130) drives the indoor squirrel-cage blower that circulates conditioned air through the duct system, while the 1/5 HP, 810 RPM condenser fan motor (OEM 1186359) pulls air across the outdoor coil to reject heat during cooling. A failed motor shows up as no airflow, weak airflow, a humming motor that won't start, or a motor that runs hot and trips on its internal overload. Worn bearings produce a rumble or squeal that gets louder over time.

Specifications

Spec Value
Part Number 1188130 (blower), 1186359 (condenser)
Type Blower motor / condenser fan motor
Brand ICP (Tempstar / Heil)
Horsepower 1/2 HP (blower), 1/5 HP (condenser)
Speed 810 RPM (condenser fan)
Voltage 208/230V
Fit OEM direct replacement

Compatibility

Direct fit for the ICP / Tempstar / Heil WPG4424090RKB1 packaged gas-electric unit. Verify the existing motor frame, shaft diameter, rotation, and HP against OEM 1188130 or 1186359 before ordering, and reuse a run capacitor only if it matches the new motor's MFD rating.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter. Capacitors hold a charge — discharge before handling.
  2. Access — Remove the service panel covering the blower or condenser section.
  3. Document — Photograph all motor leads, the capacitor wiring, and the fan-blade position on the shaft.
  4. Remove — Loosen the blade/blower set screw, pull the wheel or fan, disconnect leads, and unbolt the motor from its mount.
  5. Install — Mount the new motor, set the blade at the documented depth, reconnect leads per your photo, and confirm correct rotation direction.
  6. Test — Restore power, run the unit, and verify smooth startup, correct airflow, and no overheating.

Signs You Need a Replacement

  • No airflow or weak airflow from the registers
  • Motor hums but won't start, or starts only with a hand-spin
  • Grinding, squealing, or rumbling bearing noise
  • Motor runs hot and trips its thermal overload

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4424090RKB1 — Furnace Blower | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4424090RKB1 — Furnace Blower | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4424090RKB1 — Furnace Blower | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online