Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 1/2 HP Blower Motor for WPG4244040LKB1 — OEM Furnace Fan Motor | Ships Today
ICP

ICP 1/2 HP Blower Motor for WPG4244040LKB1 — OEM Furnace Fan Motor | Ships Today

SKU: 1188128 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 1/2 HP blower motor is the direct-fit indoor fan motor for the ICP / Heil / Tempstar / Comfortmaker WPG4244040LKB1 furnace. It drives the blower wheel that moves conditioned air through the supply ductwork on both heating and cooling cycles. A failed blower motor is a primary cause of weak airflow, overheating limit trips, and complete no-air conditions. Covered OEM part number: 1188128 (Motor Blower 1/2 HP). Worn bearings, an open winding, or a failed start capacitor will stall the motor and force the furnace into a high-limit lockout. This direct replacement restores rated airflow and protects the heat exchanger from overheating.

Specifications

Spec Value
Part Number 1188128
Type Blower / Indoor Fan Motor
Brand ICP / Heil / Tempstar / Comfortmaker
Horsepower 1/2 HP
Voltage 115V
Application Furnace Blower

Compatibility

Built for the WPG4244040LKB1 and used across matching ICP-built furnace platforms sold under the Heil, Tempstar, Comfortmaker, and Arcoaire names. Verify horsepower, voltage, rotation, and shaft size against the failed motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel and slide out the blower assembly.
  3. Document — Photograph all motor leads, the capacitor wiring, and the wheel set-screw position.
  4. Remove — Loosen the blower wheel set screw, pull the wheel, and unbolt the old motor from the mounting band.
  5. Install — Mount the new motor, reinstall the wheel at the same depth, and reconnect leads per your photo.
  6. Test — Restore power, run heat and cool cycles, and confirm smooth, quiet operation at full airflow.

Signs You Need a Replacement

  • Blower hums but will not start, or starts only with a spin
  • Weak airflow at the registers and short-cycling on the limit
  • Grinding, squealing, or rumbling bearing noise
  • Hot motor body, burning smell, or repeated breaker trips

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4244040LKB1 — OEM Furnace Fan Motor | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4244040LKB1 — OEM Furnace Fan Motor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4244040LKB1 — OEM Furnace Fan Motor | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online