Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Heil X-13 Blower Motor for WPG4244040LKA1 — 1/2 HP ECM | Ships Today
ICP

Heil X-13 Blower Motor for WPG4244040LKA1 — 1/2 HP ECM | Ships Today

SKU: 1186862 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 1/2 HP X-13 blower motor (Part No. 1186862) for the ICP/Tempstar/Heil model WPG4244040LKA1. The X-13 is a constant-torque ECM (electronically commutated motor) that drives the indoor blower wheel, moving conditioned air through the supply ductwork during heating, cooling, and fan-only operation. Compared to a standard PSC motor, the X-13 delivers higher efficiency, soft starts, and programmed airflow tied to multiple tap settings. Symptoms of a failing motor include no airflow from the registers, a blower that won't start or only hums, intermittent operation, overheating and thermal cutout, or noisy/grinding bearings. Because the indoor blower is essential to both heating and cooling, a dead X-13 takes the entire system offline.

Specifications

Spec Value
Part Number 1186862
Type X-13 Constant-Torque ECM Blower Motor
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Voltage 120 VAC
Application Indoor Furnace / Air Handler Blower

Compatibility

Engineered as the OEM replacement for ICP/Tempstar/Heil model WPG4244040LKA1. This 1/2 HP X-13 motor is used across many furnaces and air handlers in the same brand family that specify a constant-torque ECM blower. Verify the part number, horsepower, and tap configuration against your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment access panel.
  3. Document — Photograph the motor harness, tap connections, and blower wheel position before disconnecting.
  4. Remove — Disconnect the motor leads and control plug, loosen the wheel set screw, and slide the blower assembly out to free the old motor.
  5. Install — Transfer the blower wheel, mount the new X-13 motor, set the wheel position, and reconnect the harness and taps per your photo.
  6. Test — Restore power and verify smooth start-up, correct airflow on each speed tap, and quiet operation.

Signs You Need a Replacement

  • No airflow from supply registers on heat, cool, or fan
  • Blower hums but won't spin, or starts intermittently
  • Motor overheats and trips its thermal protector
  • Grinding, rattling, or worn-bearing noise from the blower

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG4244040LKA1 — 1/2 HP ECM | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG4244040LKA1 — 1/2 HP ECM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG4244040LKA1 — 1/2 HP ECM | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online