Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Heil Hot Surface Igniter with Wiring Kit for RGS120LRCB0AAA — OEM Ignitor | Ships Today
ICP

Heil Hot Surface Igniter with Wiring Kit for RGS120LRCB0AAA — OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part 1171306) bundled with its matched igniter wiring kit (part 1188370) for the ICP / Tempstar / Heil RGS120LRCB0AAA gas furnace. On a call for heat, the furnace control board sends line voltage to the igniter, which heats to a glowing temperature and lights the burner gas. Hot surface igniters are brittle and degrade over time — the element develops hairline cracks or hot spots until it can no longer reach ignition temperature. Including the wiring kit ensures the connector and leads are fresh, avoiding the intermittent no-ignition faults caused by a brittle or heat-damaged harness.

Specifications

Spec Value
OEM Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot surface igniter
Brand ICP / Tempstar / Heil
Fitment OEM direct replacement
Application Gas furnace burner ignition

Compatibility

Designed for the ICP-family RGS120LRCB0AAA gas furnace and related ICP, Tempstar, Heil, and Comfortmaker furnaces using OEM igniter 1171306 with wiring kit 1188370. Verify your existing igniter part number and mounting bracket style before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner access panel.
  3. Document — Photograph the igniter position, bracket, and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out — handle only by the ceramic base, never the fragile element.
  5. Install — Mount the new igniter so the element sits in the burner flame path, install the new wiring kit, and reconnect the harness.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • Furnace ignites no heat / igniter never glows
  • Visible cracks, chips, or white hot spots on the element
  • Intermittent ignition or repeated ignition lockouts
  • Brittle, melted, or discolored igniter wiring or connector

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS120LRCB0AAA — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS120LRCB0AAA — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS120LRCB0AAA — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online