Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Heil Hot Surface Igniter Kit for RGS150LDCB0AAAA — With Wiring Harness | Ships Today
ICP

Heil Hot Surface Igniter Kit for RGS150LDCB0AAAA — With Wiring Harness | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) and matching igniter wiring kit (part 1188370) provide reliable ignition for the ICP/Tempstar/Heil RGS150LDCB0AAAA gas furnace. On each heat call the furnace control board sends line voltage to the igniter, which glows red-hot to ignite the gas at the burners. Igniters are a wear item — the silicon carbide or silicon nitride element grows brittle with thousands of heating cycles and eventually cracks, leaving the furnace unable to light. The included wiring kit ensures the connector and harness match the furnace control, avoiding the melted or corroded plugs that often accompany an aged igniter.

Specifications

Spec Value
OEM Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + Wiring Harness Kit
Application Gas Furnace Burner Ignition
Fits Model RGS150LDCB0AAAA

Compatibility

Designed as the factory replacement igniter assembly for the ICP/Tempstar/Heil RGS150LDCB0AAAA and other same-generation Carrier-family gas furnaces using a hot surface ignition system. The bundled wiring kit lets you replace the harness at the same time when the original connector is heat-damaged.

Installation Guide

  1. Safety First — Shut off gas and electrical power, then verify zero voltage with a multimeter before servicing.
  2. Access — Remove the furnace burner compartment door.
  3. Document — Photograph the igniter position and the wiring harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the fragile igniter — never touch the element with bare fingers.
  5. Install — Mount the new igniter so the element sits in the burner flame path, then connect the new wiring kit to the control board.
  6. Test — Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light within the normal ignition sequence.

Signs You Need a Replacement

  • Furnace clicks and the inducer runs but the burners never light
  • Igniter shows no glow or only a dim, uneven glow
  • Visible cracks or breaks in the igniter element
  • Control board locks out after several failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LDCB0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LDCB0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LDCB0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera